Flocculator Mixer Priced Selection Guide: Basis 15 minute detention time per Floc Mixer.  

Tank volume or sectioned floc basin tank volume vs. mixer selection.

Torque Ratio = 1 {1 horsepower @ 1750 RPM}

Model AQO3X Heavy Duty Gear Driven Fixed Flanged Plate Mounted Mixers - Pricing Matrix

All pricing in US dollars, FOB factory.

Motor Class F insulated, tropicalized, SF=1.15, chemical duty motor, 230/460 volt, 3 phase , 60 hertz. 

SWD,
feet
Priced Flocculator Mixers Complete: Side Water Depth vs. Basin L x W, Gallons
L x W, Feet 8x8 10x10 12x12 14x14 16x16 18x18 20x20 22x22 24x24 26x26
8 Volume Gallon 3,831 5,985 8.619 11,731 15,322 19,392 23,941 28,968 34,475 40,460
Torque Ratio 0.33 0.33 0.33 0.50 0.75 1.0 1.0 1.0 1.0 1.0
Price Each CF CF CF CF CF CF CF CF CF CF
9 Volume Gallon 4,309 6,733 9,696 13,197 17,237 21,816 26,933 32,589 38,784
Torque Ratio 0.33 0.33 0.33 0.50 0.75 1.00 1.0 1.0 1.0
Price Each CF CF CF CF CF CF CF CF CF
10 Volume Gallon 4,788 7,482 10,773 14,664 19,153 24,240 29,926 36,210
Torque Ratio 0.33 0.33 0.50 0.75 1.0 1.0 1.0 1.0
Price Each CF CF CF CF CF CF CF CF
11 Volume Gallon 5,267 8,230 11,851 16,130 21,068 26,664 32,919
Torque Ratio 0.33 0.33 0.50 0.75 1.0 1.0 1.0
Price Each CF CF CF CF CF CF CF
12 Volume Gallon 5,746 8,978 12,928 17,596 22,983 29,088
Torque Ratio 0.33 0.33 0.75 0.75 0.75 1.00
Price Each CF CF CF CF CF CF
13 Volume Gallon 6,225 9,726 14,005 19,063 24,898 31,512
Torque Ratio 0.33 0.5 0.75 0.75 1.0 1.00
Price Each CF CF CF CF CF CF
14 Volume Gallon 6,703 10,474 15,083 20,529 26,814
Torque Ratio 0.5 0.75 0.75 0.75 1.0
Price Each CF CF CF CF CF

Floc Chamber Volume in Gallons; Torque Ratio as compared to a 1 horsepower motor at 1750 RPM; SWD-Side Water Depth, feet; L-Basin Length, feet; W-Basin Width, feet.  Design Basis: 15 minute detention or retention time.  Generally, two 15-minute retention time tanks in series are required.  All designs have minimum  AGMA service factor of 1.9 based upon motor nameplate horsepower (Moderate Shock Loading service factor > 1.5).  All pricing in US dollars.      

Engineers prefer to use at least a 1.0 horsepower motor at 1750 RPM, or its equivalent, for all top entering flocculators designs.  Selections denoting "< 1.0 torque ratio" indicate that all that is required is a motor less than 1.0 horsepower motor, which has been applied to the design, to meet the flow criteria.  Each of these designs can be supplied with a 1 horsepower @ 1750 RPM motor or its equivalent, maintaining the minimum AGMA service factor rating of 1.9 (moderate shock loading) based /upon motor nameplate horsepower, for a slight price modification.  These selections, as indicated and priced, will have an actual power draw less than the stated horsepower as smaller diameter impellers have been used to handle each volumes process requirement.  